Refine your search:     
Report No.
 - 
Search Results: Records 1-5 displayed on this page of 5
  • 1

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

JAEA Reports

Estimation of exchange time for neutron startup sources of HTTR

Ono, Masato; Kozawa, Takayuki; Fujimoto, Nozomu*

JAEA-Technology 2019-012, 15 Pages, 2019/09

JAEA-Technology-2019-012.pdf:2.83MB

The High Temperature Engineering Test Reactor has a neutron source of $$^{252}$$Cf to start up the reactor and to confirm count rates of wide range monitors. The half-life of $$^{252}$$Cf is short, about 2.6 years, so it is necessary to replace at an appropriate time. In order to estimate the period to replace, it is necessary to consider not only the half-life but also the fluctuation of the count rate of the wide range monitor to prevent alarm. For that reason, the method has been derived to predict a minimum count rate from relationship between the count rate and the standard deviation of the count rate of the wide range monitors. As a result of predicting the count rate using this method, it was found that the minimum count rate reaches to 3.0cps in 2022 and 1.5 cps in 2024. Therefore, it is necessary to exchange $$^{252}$$Cf by 2024.

Journal Articles

Development of the prediction technology of cable disconnection of in-core neutron detector for the future high-temperature gas-cooled reactors

Shimazaki, Yosuke; Sawahata, Hiroaki; Kawamoto, Taiki; Suzuki, Hisashi; Shinohara, Masanori; Honda, Yuki; Katsuyama, Kozo; Takada, Shoji; Sawa, Kazuhiro

Journal of Nuclear Engineering and Radiation Science, 2(4), p.041008_1 - 041008_5, 2016/10

Maintenance technologies for the reactor system have been developed by using the high-temperature engineering test reactor (HTTR). One of the important purposes of development is to accumulate the experiences and data to satisfy the availability of operation up to 90% by shortening the duration of the periodical maintenance for the future HTGRs by shifting from the time-based maintenance to condition-based maintenance. The technical issue of the maintenance of in-core neutron detector, wide range monitor (WRM), is to predict the malfunction caused by cable disconnection to plan the replacement schedule. This is because that it is difficult to observe directly inside of the WRM in detail. The electrical inspection method was proposed to detect and predict the cable disconnection of the WRM by remote monitoring from outside of the reactor by using the time domain reflectometry and so on. The disconnection position, which was specified by the electrical method, was identified by non-destructive and destructive inspection. The accumulated data is expected to be contributed for advanced maintenance of future HTGRs.

Journal Articles

Development of the prediction technology of cable disconnection of in-core neutron detector for the future high-temperature gas cooled reactors

Shimazaki, Yosuke; Sawahata, Hiroaki; Kawamoto, Taiki; Suzuki, Hisashi; Shinohara, Masanori; Honda, Yuki; Katsuyama, Kozo; Takada, Shoji; Sawa, Kazuhiro

Proceedings of 23rd International Conference on Nuclear Engineering (ICONE-23) (DVD-ROM), 7 Pages, 2015/05

Maintenance technologies for the reactor system have been developed by using the high-temperature engineering test reactor (HTTR). One of the important purposes of development is to accumulate the experiences and data to satisfy the availability of operation up to 90% by shortening the duration of the periodical maintenance for the future HTGRs by shifting from the time-based maintenance to condition-based maintenance. The technical issue of the maintenance of in-core neutron detector, wide range monitor (WRM), is to predict the malfunction caused by cable disconnection to plan the replacement schedule. This is because that it is difficult to observe directly inside of the WRM in detail. The electrical inspection method was proposed to detect and predict the cable disconnection of the WRM by remote monitoring from outside of the reactor by using the time domain reflectometry and so on. The disconnection position, which was specified by the electrical method, was identified by non-destructive and destructive inspection. The accumulated data is expected to be contributed for advanced maintenance of future HTGRs.

JAEA Reports

Neutron response analysis of wide range detector in High Temperature Engineering Test Reactor (HTTR)

Murata, Isao; Yamashita, Kiyonobu; Shindo, Ryuichi; Shiozawa, Shusaku; *

JAERI-Tech 95-036, 101 Pages, 1995/07

JAERI-Tech-95-036.pdf:2.46MB

no abstracts in English

Journal Articles

A Wide range personnel neutron dosimeter based on a proportional counter

H.J.Delafield*; W.G.Sparke*; ; W.R.Loosemore*; J.A.Dennis*

Nucleonic Instrumentation IEE Conference Publication No.47, p.223 - 228, 1968/00

no abstracts in English

5 (Records 1-5 displayed on this page)
  • 1